Easy to Transport, Easy to Use
Mobil MAGG is a combination pre-conditioned air unit and 400 Hz ground power unit designed to fit in the volume of about one-third a standard ISO container. The unit is designed to service the Gripen fighter and others in extreme cold environments. Using utility power or power from a diesel generator, the Mobil MAGG is ready to ship anywhere, anytime supplying the conditioned air and power you need for your defense fighters.
Features & Benefits
Pre-Conditioned Air (PCA)
The Pre-Conditioned Air (PCA) system produces high-pressure, chilled air to keep avionics on the aircraft cool while 400 Hz power is applied. The module utilizes both a refrigerant direct-expansion system and a custom-designed, glycol air-to-air heat exchanger. Two outputs provide cooling for up to two aircraft simultaneously and each feature a manually actuated valve. A unique design element is the secondary glycol cooling system for use in extreme cold-weather conditions — when the direct-expansion module would be severely degraded (below 14⁰F).
400 Hz Power
The 400 Hz system uses a solid-state power converter that accepts incoming 400 VAC, 50 Hz power (60Hz Option) and generates 115 VAC, 400 Hz power. The system is nominally rated at 45 kVA and supplies two 22.5 kVA outputs. The 400 Hz system is interlocked with the PCA system.
A solar power augmentation system is also part of this unique defense air and power device.
Performance Characteristics
Nominal Characteristics* | Mobil MAGG |
---|---|
Configuration | Static w/Forklift Pockets: Sized w/in ISO 20 ft Container |
Power | Utility Power Input 400/3/50 Hz with 60 Hz Option |
Aircraft (Serviced) | Gripen JAS 39, F15, 18, 35 |
Air Transportable | C-130, C 17, C 5, A400M |
Modes | Cool DX, Cool Glycol, 400 Hz Power, Diagnostics Mode |
Ambient Envelope | -51⁰ to +120⁰F/-46⁰- +49⁰C |
Weight | 8200lbs / 3719kg |
Length | 77.5in/197cm |
Width | 96in./244cm |
Height | 96in./244cm |
Nominal Pressure and Flow | 100 ppm at 5 psi, Variable 50 to 120 ppm, up to 8 psi |
Refrigerant | R134A and Glycol Loop |
Glycol Pump | 100 GPM |
400 Hz Output | Dual each 22.5 kVA, 115/200/400 Hz |
Standards | Mil Std 704F, JS-66593, ISO 9001 |
50Hz Output (Receptacle) | Dual 230/1/50 Hz and 230/400/3/50 Hz |